Start main contents

  • Register
  • Login

Print Page

Font Size:
MI5000

Realizes real-time control and edge computing function

Highly accurate device control by CC-Link IE field network with edge computing function enabling data collection/analysis in the middle level between the IT system and shop floor.



Overview

Windows® and VxWorks® installed

Two types of operating systems can be operated at the same time, VxWorks® with real-time device control and data collection , analysis of collected data, display of analysis result can perform processing that is good for each OS like Windows® . As a result, we can consolidate device control and information processing functions, which we have corresponded to by combining PCs and dedicated devices in the past, contributing to reduction of system construction cost and space saving of equipment.



Easy to exchange data between OS

By passing through shared memory and shared folders, it is easy to pass data between OS's


Windows® individual restart possible

Even when Windows® freezes, you can restart Windows® only while running VxWorks® .


Highly accurate device control by CC-Link IE field network

It can communicate control information and production information of equipment connected by CC-Link IE field network at the fastest 1 ms. Therefore, we can realize highly accurate device control and high speed collection of production information. CC-Link IE field network, CC-Link IE field network Basic port, so you can easily connect to compatible equipment simply by making settings.



Hardware features

General Purpose Sequencer Since it has high environmental resistance and durability cultivated in the MELSEC series, long-term continuous operation is possible in various environments used by customers. Also, since expendable items are easily removable and replaceable, maintenance can be done easily.


Specification

Series name
Item name
Model name
Performance specification
hardwareMPU
Main memory
Internal storagecapacity
Extended storageinterface
Maximum capacity
softwareOS
Programming language
Dedicated API provided form
Display Interfaceinterface
resolution
RS-232Number of channels
Transmission speed
USBUSB 3.0
USB 2.0
Input / output terminalShutdown request input
Shutdown completion notification output
Power supply (AC input)Rated input voltage
Input voltage variable range
Input frequency
Input maximum apparent power
External dimensions (H) x (W) x (D)
mass
Network specification
Ethernetinterface
Number of channels
CC-Link IE field networkStation type
communication speed
Maximum number of connected stations
Number of ports
communication cable
Transmission path format
Total extension distance
Maximum Inter-Station Distance
CC-Link IE Field Network BasicStation type
Station typeNumber of slave stations connected in one network
Number of ports
Transmission path format
MI 5000
MELIPC body
 
Intel ® Core ™ i7 - 5700 EQ 2.6 GHz (Quad Core)
Windows ® : 12 GB 
VxWorks ® : 1 GB * 1
Windows ® : 45 GB 
VxWorks ® : 4 GB
Windows ® : Cfast card × 1 
VxWorks ® : -
Windows ® : 64 GB 
VxWorks ® : -
Windows ® : Windows ® 10 IoT Enterprise 2016 LTSB (64 bit version) 
VxWorks ® : VxWorks ® 7.0
Windows ® : Language supported by the above OS 
VxWorks ® : C / C ++
Windows ® : Standard DLL 
VxWorks ® : C / C ++ format
Windows ® : DisplayPort × 1 
VxWorks ® : -
Windows ® : Up to 3840 × 2160 * 2
VxWorks ® : -
* 3
9600 to 115200 bps
2
2
AC 100 to 240 V
AC 85 - 264 V
47 - 63 Hz
139 VA or less (AC 240 V maximum load, power on)
106 × 362 × 119 mm
2674 g
 
10 BASE-T / 100 BASE-TX / 1000 BASE-T
Windows ® : 1 (CH 2) 
VxWorks ® : 1 (CH 1)
Master station and local station
1000 Mbps
120 units * 4
1
Ethernet cable (category 5e or more, with double shield · STP, straight cable)
Line type, star type * 5
Line type: 12,000 m, star type: It depends on system configuration.
100 m (conforming to ANSI / TIA / EIA - 568 - B (category 5 e))
Master station
64 units (16 units x 4 groups) * 6
1
Star type

* 1 The shared memory is 0.25 GB.

* 2 Maximum resolution at 60 Hz.

* 3 It can be assigned to Windows ® part or VxWorks ® part by parameter setting .

* 4 Up to 120 slave stations can be connected.

* 5 For the star type, please use a switching hub that supports CC-Link IE field network synchronous communication.

* 6 Maximum number of slave stations that can be managed by the master station. The maximum number of connected units varies depending on the number of stations occupied by the slave stations. However, the total number of occupied stations should not exceed the maximum number of connected units.

Operating ambient temperature
Storage ambient temperature
Ambient operating humidity
Storage ambient humidity
Anti-vibrationMeets JIS B 3502, IEC 61131-2When there is intermittent vibration
When there is continuous vibration
Impact resistance
Use atmosphere
Used altitude [m]
Installation location / place of use
Over Voltage Category
Pollution degree
Device class
0 to 55 ° C
-25 to 75 ° C * 7
5 to 95% RH, non condensing
5 to 95% RH, non condensing * 7
Frequency: 5 to 
8.4 Hz , Shoulder amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Low acceleration: 9.8 m / s 2
Sweep count: 10 times in X, Y, Z directions
Frequency: 5 to 
8.4 Hz, Shoulder amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Low acceleration: 4.9 m / s 2
Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , three times in each of X, Y, Z)
There is no corrosive gas, flammable gas, conductive dust is not serious
0 to 2000 * 8 * 9
In control panel 10
Ⅱ or less 11
2 or less * 12
Class I

* 7 The storage ambient temperature of the fan unit is -25 to 70 ° C, and the stored ambient humidity is 20 to 85%.

* 8 Do not use or store in an environment pressurized to atmospheric pressure of 0 m altitude. If used, there is a possibility of malfunction.

* 9 When using in high altitudes exceeding 2000 m altitude, the upper limit of the withstand voltage performance and ambient operating temperature drops.

* 10 When installing a ventilation fan in the control panel, consider arranging the ventilation fan so as not to interfere with the exhaust flow from the fan unit of this product.

* 11 Indicates where the device is assumed to be connected to the power distribution unit from the public power distribution network to the machinery in the premises. Category II is applied to equipment supplied from fixed equipment. The surge withstand voltage of the equipment rated up to 300 V is 2500 V.

* 12 Indicates the degree of generation of conductive material in the environment where the equipment is used. Pollution Degree 2 produces only nonconductive pollution. However, it is an environment where temporary conduction can occur by accidental condensation.

Others

System Configuration

By using preinstalled software, you can easily collect Mitsubishi Electric FA equipment data. Furthermore, data of other company's products can be easily collected with additional software. Primary processing of the collected data reduces data capacity to be transmitted to the host system and prevents data delay etc.


Related Solutions