Product Features
![](../files/product/img_301121_103609490753722.jpg)
Read various codes
The code reader CF26 is equipped with 2-D code reading algorithm PowerGrid™ and 1-D code image processing algorithm HotBarsⅡ™. PowerGrid™ technology provides reliable reading of challenging 2-D codes which exhibit damage to or complete elimination of the finder pattern, clocking pattern, and quiet zone. In addition, HotBarsⅡ™ delivers reading of reflected, damaged or poorly printed 1-D codes as small as 0.8 pixels per module.
Reliably read codes with difficult conditions
A combination of high-powered light, polarized front cover and liquid lens provides a good reading condition. Codes at long working distances, on high-speed application, on round, shiny, highly reflective, or specular surfaces can be reliably read.
![Codes on the round surface](https://www.mitsubishielectric.com/fa/products/snsr/sensor/pmerit/cr/features/images/feat_02_1.jpg)
![Codes on the shiny and highly reflective surface](https://www.mitsubishielectric.com/fa/products/snsr/sensor/pmerit/cr/features/images/feat_02_2.jpg)
![Codes moving at high speed](https://www.mitsubishielectric.com/fa/products/snsr/sensor/pmerit/cr/features/images/feat_02_3.jpg)
Codes in different locations and heights
A wide-field code reader equipped with unique algorithm can read codes in different locations and depths. This is ideal for codes in different locations such as cartons with different heights on the moving conveyor.
Easy installation reduces setup cost
Embedded autofocus function
Integrated code reader
- High-power illumination is integrated
Four high-powered red LED illuminations provide an optimum illumination condition. The code reader has integrated lighting and does not require angle adjustment of illumination. Additionally, hardware cost can be reduced by eliminating the need for separate illumination.
- Liquid lens
The code reader uses liquid lenses which do not have any moving parts that can wear out or fail, thereby reducing maintenance cost.
Customizable according to installation conditions
Configuration can be changed according to the installation space
The configuration can be changed between in-line and right-angle. By changing the configuration according to the installation space, the code reader can be installed by the wall or in tight spaces where wiring orientation is constrained.
Compact palm size
Working distance
CF26-SR (6.2 mm lens)
Reading distance and minimum cell size (unit: mm)
Distance | 1-D code | 2-D code |
---|---|---|
40 | 0.0508 | 0.0762 |
65 | 0.0508 | 0.1016 |
105 | 0.127 | 0.1778 |
Minimum code sizes per single cell that can be read in each working distance
CF26-LR (16 mm lens)
Reading distance and minimum cell size (unit: mm)
Distance | 1-D code | 2-D code |
---|---|---|
80 | 0.0508 | 0.0508 |
150 | 0.0508 | 0.0762 |
190 | 0.0508 | 0.1016 |
225 | 0.0762 | 0.1016 |
375 | 0.1016 | 0.1778 |
500 | 0.1524 | 0.254 |
1000 | 0.381 | 0.508 |
Minimum code sizes per single cell that can be read in each working distance