![](../files/product/img_301121_095628121176621.jpg)
Improved maintainability
and preventive maintenance support stable system operation.
![](http://www.mitsubishifa.co.th/files/upload/img_220823_0201201301827513.png)
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
Real-time monitoring for early fault detection
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
![E800-SCE](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_sce_on.png)
- Load characteristics fault detection function
When a mechanical fault such as clogging of the filter occurs, the inverter outputs a warning or shuts off the output to prevent system damage.
The speed–torque characteristic is stored while no fault occurs, enabling comparison between the measured data and the stored data.
![](http://www.mitsubishifa.co.th/files/upload/img_220823_0201301405496159.png)
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
Supporting scheduled maintenance planning
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
![E800-SCE](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_sce_on.png)
![](http://www.mitsubishifa.co.th/files/upload/img_220823_020140523025852.jpg)
- Environmental impact diagnosis function
The world's first*1 “Corrosive-Attack-Level Alert System (CALAS™)”*2 makes it possible to identify signs of inverter damage caused by corrosive gas such as hydrogen sulfide*3. This function notifies operators when factors such as the production environment need to be improved, resulting in reduction in the equipment downtime (for coated models (-60/-06) only).
The combined resistance of multiple metal corrosion sensors is measured to detect the level of degree of metal part corrosion caused by corrosive gas in the air.
- *1:According to our investigation as of September 10, 2019.
- *2:Patent applied for.
Alert system for the risk of corrosive damage (degree of corrosion) of electrical equipment - *3:Others will be supported in future.
![](http://www.mitsubishifa.co.th/files/upload/img_220823_020150821175619.png)
![](http://www.mitsubishifa.co.th/files/upload/img_220823_020200958812145.png)
- *5:Terminals A, B, and C of the inverter
- Enhanced life diagnosis function
Availability of life diagnosis checks is extended as compared to the FR-E700 series. This enhanced diagnosis function ensures reliable operation of the system.
The design life of cooling fans and capacitors has been extended to 10 years*4.
- *4:Surrounding air temperature: annual average 40°C (free from corrosive gas, flammable gas, oil mist, dust and dirt)
Output current: 80% of the inverter ND rating
Since the design life is a calculated value, it is not a guaranteed value.
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
Supporting preventive maintenance of peripherals
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
![E800-SCE](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_sce_on.png)
- Maintenance timer
The Maintenance timer signal is output when the inverter's cumulative energization time reaches the time period set with the parameter. This can be used as a guide for when the maintenance of the equipment should be conducted.
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
Thorough customer support
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
![E800-SCE](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_sce_on.png)
![](http://www.mitsubishifa.co.th/files/upload/img_220823_020210757744411.jpg)
- FA Center network
Our global network offers reliable technical support and customer satisfaction.
- Setup information web page
Our setup information web page provides easy access to manuals, videos, and outline dimension drawings.