Print Page

Font Size:
Product

Product Features

FX3S, FX3G, FX3GC, FX3UC series positioning function (main unit: transistor output type)

FX3S, FX3G, FX3GC, FX3UC series positioning function (main unit: transistor output type)

  • Low cost system can be realized without any special expansion devices dedicated for positioning.
  • 1-speed positioning and repetitive positioning can be easily performed by the PLC alone.
  • Dedicated positioning instructions are built-in. With the new batch setting positioning instruction (DTBL), positioning can be executed just by specifying in the PLC program the number of a positioning operation set in GX Developer.
    (FX3S: DTBL instruction is not supported)
  • 3 independent axes can output maximum 100kHz pulse train from outputs Y000, Y001, Y002 (transistor output).
    (FX3S and FX3G 14pt/24pt models and FX3GC have 2 independent axes)

Example system configuration

Example system configuration

*1: FX3S and FX3G 14 pt/24 pt models and FX3GC have 2 independent axes.

Batch Data Positioning Mode (DTBL) instruction

Batch Data Positioning Mode (DTBL) instruction

InstructionDescription
DVIT(FNC151)*2Interrupt Positioning
PLSV(FNC157)Variable Speed Pulse Output
DRVI(FNC158)Drive to Increment
DRVA(FNC159)Drive to Absolute

*2: only FX3U/FX3UC PLCs

Specifications

ItemsSpecifications
Pulse OutputY000, Y001, Y002* of transistor output type main unit can each output maximum 100kHz (3 independent axes, FX3S and FX3G 14pt/24pt models and FX3GC have 2 axes).
Rotation direction signal output included
Output (Y000 to Y002*)Transistor output: Open collector (use transitor output type main unit)
Use voltage, current range: 5 to 24 V DC/ 10 to 100 mA
Programming languages[Pulse output instructions: 2 types]
Pulse output (PLSY), pulse output with acceleration deceleration (PLSR)

*: FX3S and FX3G 14pt/24pt models and FX3GC have Y000 to Y001.