Product
Product Features
Load cell
Interface with all types of load cell with the load cell I/P module
● Load cell input moduleQ61LD
Load cells can now be directly connected to the programmable controller system without requiring an external signal converter.
The module achieves highly accurate measurement with steady data conversion speed that guarantees the accuracy of load cells.
Separate signal converter not required!
Reduce engineering costs by directly connecting a load cell to the programmable controller!
- ● Any type of load cell*1 such as magnetostriction, capacitive, gyroscope, or strain gauge.
- ● 6-wire system (combination of remote sensing and ratiometric methods) or 4-wire system load cells.
*1: Within 5 V DC of applied voltage, and 60 mA of output current. (4 units can be connected in parallel with 350 Ω type load cells)
- ● Applications requiring high accuracy can be achieved by connecting the load cell directly to the programmable controller.
Zero offset function
Static load calibration function
Input signal error detection function
Lineup
Number of channels | Channel isolated | Load cell |
---|---|---|
1 | ● | Q61LD |