MR-JE-C (Ethernet Interface) Specifications

Servo amplifier model MR-JE-10C20C40C70C100C200C300C
OutputRated voltage3-phase 170 V AC
Rated current[A]1.11.52.85.86.011.011.0
Power supply inputVoltage/frequency (Note 1)3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz (Note 7)3-phase 200 V AC
to 240 V AC,
50 Hz/60 Hz
Rated current (Note 6)[A]0.91.52.63.85.010.514.0
Permissible voltage fluctuation3-phase or 1-phase 170 V AC to 264 V AC3-phase or 1-phase 170 V AC to 264 V AC (Note 7)3-phase
170 V AC
to 264 V AC
Permissible frequency fluctuation±5% maximum
Interface power supply24 V DC ± 10% (required current capacity: 0.3 A)
Control methodSine-wave PWM control/current control method
Permissible regenerative power of the built-in regenerative resistor (Note 2, 3)[W]--102020100100
Dynamic Brake (Note 4)Built-in
Communication functionEthernet (Note 8)Connect a master station (controller), a personal computer, etc. (MR Configurator2 compatible)
USBConnect a personal computer (MR Configurator2 compatible)
Encoder output pulseCompatible (A/B/Z-phase pulse)
Position control modeMaximum input pulse frequency4 Mpulses/s (when using differential receiver), 200 kpulses/s (when using open-collector)
Positioning feedback pulseEncoder resolution: 131072 pulses/rev
Command pulse multiplying factorElectronic gear A/B multiple, A: 1 to 16777215, B: 1 to 16777215, 1/10 < A/B < 4000
Positioning complete width setting0 pulse to ±65535 pulses (command pulse unit)
Error excessive±3 rotations
Torque limitSet by parameters or external analog input (0 V DC to +10 V DC/maximum torque)
Speed control modeSpeed control rangeAnalog speed command 1:2000, internal speed command 1:5000
Analog speed command input0 V DC to ±10 V DC/rated speed (Speed at 10 V is changeable with [Pr. PC12].)
Speed fluctuation rate±0.01% maximum (load fluctuation 0% to 100%), 0% (power fluctuation: ±10%) ±0.2% maximum (ambient temperature: 25 ℃ ± 10 ℃) only when using analog speed command
Torque limitSet by parameters or external analog input (0 V DC to +10 V DC/maximum torque)
Torque control modeAnalog torque command input0 V DC to ±8 V DC/maximum torque (input impedance: 10 kΏ to 12 kΏ)
Speed limitSet by parameters
Profile modeProfile position modeCommand position rangeSet by objects Setting range of feed length: -2147483648 to 2147483647 [pulse], Setting range of rotation angle: -360.000 to 360.000 [degree]
Command multiplying factorElectronic gear A/B multiple, A: 1 to 16777215, B: 1 to 16777215, 1/27649 < A/B < 8484
Positioning complete width setting0 pulse to ±65535 pulses (command pulse unit)
Error excessive±3 rotations
Torque limitSet by parameters or objects
Profile velocity modeCommand speed range-21474836.48 to 21474836.47 r/min (Fixed to the permissible speed)
Torque limitSet by parameters or objects (Fixed to the maximum torque)
Profile torque modeCommand torque range-3276.8 to 3276.7% (Fixed to the maximum torque)
Speed limitSet by parameters or objects (Fixed to the permissible speed)
Homing modeMitsubishi Electric original methodDog type, count type, data set type, stopper type, home position ignorance (servo-on position as home position), dog type rear end reference, count type front end reference, dog cradle type, dog type adjacent Z-phase reference, dog type front end reference, dogless Z-phase reference
CiA 402 methodHoming on positive home switch and index pulse (method 3, 4), Homing on negative home switch and index pulse (method 5, 6), Homing on home switch and index pulse (method 7, 8, 11, 12), Homing without index pulse (method 19, 20, 21, 22, 23, 24, 27, 28), Homing on index pulse (method 33, 34), Homing on current position (method 35, 37)
Servo functionsAdvanced vibration suppression control II, adaptive filter II, robust filter, auto tuning, one-touch tuning, tough drive function, drive recorder function, machine diagnosis function, power monitoring function, lost motion compensation function
Protective functionsOvercurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, error excessive protection
Compliance with global standardsRefer to "Compliance with Global Standards and Regulations" in the instruction manual.
Structure (IP rating)Natural cooling, open (IP20)Force cooling, open (IP20)
Close mounting (Note 5)3-phase power supply inputPossible
1-phase power supply inputPossibleNot possible
EnvironmentAmbient temperatureOperation: 0 ℃ to 55 ℃ (non-freezing), storage: -20 ℃ to 65 ℃ (non-freezing)
Ambient humidityOperation/storage: 5 %RH to 90 %RH (non-condensing)
AmbienceIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude2000 m or less above sea level (Note 9)
Vibration resistance5.9 m/s2 at 10 Hz to 55 Hz (directions of X, Y, and Z axes)
Mass[kg]0.80.80.81.51.52.12.1

Notes: 1. Rated output and speed of a servo motor are applicable when the servo amplifier is operated within the specified power supply voltage and frequency.

2. Select the most suitable regenerative option for your system with our capacity selection software.

3. Refer to "Regenerative Option" in this brochure for the permissible regenerative power [W] when a regenerative option is used.

4. When using the dynamic brake, refer to "MR-JE-_C Servo Amplifier Instruction Manual" for the permissible load to motor inertia ratio.

5. When the servo amplifiers are closely mounted, keep the ambient temperature within 0 ℃ to 45 ℃, or use the servo amplifiers with 75% or less of the effective load ratio.

6. This value is applicable when a 3-phase power supply is used.

7. When a 1-phase 200 V AC to 240 V AC power supply is used, use the servo amplifiers with 75% or less of the effective load ratio.

8. CC-Link IE field network Basic, SLMP, and MODBUS®/TCP are supported. MR Configurator2 is also connectable.

9. Refer to "MR-JE-_C Servo Amplifier Instruction Manual" for the restrictions when using the servo amplifiers at altitude exceeding 1000 m and up to 2000 m above sea level.