Product Features
![](../files/product/img_301121_095628121176621.jpg)
Downtime reduction
When a fault occurs, AI analysis and other diagnosis functions solve the problem quickly.![](http://www.mitsubishifa.co.th/files/upload/img_220823_020507602093032.jpg)
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
Streamlining the installation process
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
![E800-SCE](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_sce_on.png)
![](http://www.mitsubishifa.co.th/files/upload/img_220823_0205171840313773.jpg)
- Compatible installation size
The installation size was determined to assure exchangeability with the FR-E700 series. Installation interchange attachment options are available for facilitating replacement with the models of different size.
(The depth required for installation increases by 12 mm.)
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
Quick reaction to troubles
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
![E800-SCE](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_sce_on.png)
- Power supply from USB port
With the power supplied from the computer (USB bus power connection)*1, parameters can be set using FR Configurator2 while the main circuit power supply is OFF.
Maintenance can be performed quickly and safely.
- *1: The maximum SCCR should be 500 mA. A PU connector cannot be used during USB bus power connection.
![](http://www.mitsubishifa.co.th/files/upload/img_220823_020528572010755.png)
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
Easy and fast wiring
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
![E800-SCE](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_sce_on.png)
- Control circuit terminal
- Spring clamp terminals have been adopted for control circuit terminals for easy wiring.
Furthermore, wires can be protected against loosening or contact faults due to vibrations during operation on a bogie or during transport. No additional screw tightening is required. - The removable control circuit terminal block facilitates replacement with a new one.
FR-E800 | FR-E800-E | FR-E800-SCE | ||
---|---|---|---|---|
Input terminal | 7 | 2 | 0 | |
Output terminal | Open collector | 2 | 0 | 0 |
Relay | 1 | 1 | 1 |
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
Troubleshooting supported by AI technology
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
![E800-SCE](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_sce_on.png)
![](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/logo_maisart.jpg)
- AI fault diagnosis
The inverter is connected to the engineering software FR Configurator2 (USB/Ethernet connection).
Maisart*2 (Mitsubishi Electric's AI technology) is integrated in the software to analyze data and help identify the cause of a fault*3 (this function is enabled during speed control).
This function enables the fastest troubleshooting procedure without requiring any special skills, which contributes to downtime reduction.
- *2: Maisart is Mitsubishi Electric's brand of AI technology. The name stands for "Mitsubishi Electric's AI creates the State-of-the-ART in technology". This means that it is using our proprietary AI technology to make everything smarter.
- *3Diagnosable faults: Overcurrent trip and overvoltage trip (other faults will be supported in the future.)
![](http://www.mitsubishifa.co.th/files/upload/img_220823_0205381219852351.png)
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
Trouble analysis from a remote location
![E800](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e800_on.png)
![E800-E](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_e_on.png)
![E800-SCE](https://www.mitsubishielectric.com/fa/products/drv/inv/pmerit/fr_e/e800/images/icon_sce_on.png)
![](http://www.mitsubishifa.co.th/files/upload/img_220823_020554813439154.png)
- Trace function
Users can read the data file in FR Configurator2 for graph display or send it by e-mail to someone away from the worksite, which facilitates the trouble analysis.
- Clock function
It is possible to synchronize the internal clocks of the devices that comprise the CC-Link IE TSN communication.
- *4: The clock does not run while the control circuit power is OFF. The clock needs to be set every time after turning ON the inverter power.
By using the real-time clock function with the optional LCD operation panel (FR-LU08) (when using battery), the clock keeps running even when the control power supply is turned OFF.