FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
00CJConditional Jump
01CALLCall Subroutine
02SRETSubroutine Return
03IRETInterrupt Return
04EIEnable Interrupt
05DIDisable Interrupt
06FENDMain Routine Program End
07WDTWatchdog Timer Refresh
08FORStart a FOR/NEXT Loop
09NEXTEnd a FOR/NEXT Loop

Move and Compare

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
10CMPCompare
11ZCPZone Compare
12MOVMove
13SMOVShift Move
14CMLComplement
15BMOVBlock Move
16FMOVFill Move
17XCHExchange---
18BCDConversion to Binary Coded Decimal
19BINConversion to Binary

Arithmetic and Logical Operation

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
20ADDAddition
21SUBSubtraction
22MULMultiplication
23DIVDivision
24INCIncrement
25DECDecrement
26WANDLogical Word AND
27WORLogical Word OR
28WXORLogical Exclusive OR
29NEGNegation---

Rotation and Shift Operation

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
30RORRotation Right
31ROLRotation Left
32RCRRotation Right with Carry---
33RCLRotation Left with Carry---
34SFTRBit Shift Right
35SFTLBit Shift Left
36WSFRWord Shift Right
37WSFLWord Shift Left
38SFWRShift write
[FIFO/FILO control]
39SFRDShift read
[FIFO control]

Data Operation

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
40ZRSTZone Reset
41DECODecode
42ENCOEncode
43SUMSum of Active Bits
44BONCheck Specified Bit Status
45MEANMean
46ANSTimed Annunciator Set-
47ANRAnnunciator Reset-
48SQRSquare Root---
49FLTConversion to Floating Point*

*: Supported in FX3G series ver.1.10 and later

High-Speed Processing

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
50REFRefresh
51REFFRefresh and filter adjust---
52MTRInput Matrix
53HSCSHigh-speed counter set
54HSCRHigh-speed counter reset
55HSZHigh-speed counter zone compare
56SPDSpeed Detection
57PLSYPulse Y Output
58PWMPulse Width Modulation
59PLSRAcceleration/deceleration setup

Handy Instruction

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
60ISTInitial State
61SERSearch a Data Stack
62ABSDAbsolute drum sequencer
63INCDIncremental drum sequencer
64TTMRTeaching Timer---
65STMRSpecial Timer---
66ALTAlternate State
67RAMPRamp Variable Value
68ROTCRotary Table Control---
69SORTSORT Tabulated Data---

External FX Device

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
70TKYTen Key Input---
71HKYHexadecimal Input---
72DSWDigital switch (thumbwheel input)
73SEGDSeven Segment Decoder---
74SEGLSeven Segment With Latch
75ARWSArrow Switch---
76ASCASCII code data input---
77PRPrint (ASCII Code)---
78FROMRead From A Special Function Block-
79TOWrite To A Special Function Block-

External FX Device

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
80RSSerial Communication
81PRUNParallel Run (Octal Mode)
82ASCIHexadecimal to ASCII Conversion
83HEXASCII to Hexadecimal Conversion
84CCDCheck Code
85VRRDVolume Read*1*2-*2
86VRSCVolume Scale*1*2-*2
87RS2Serial Communication 2
88PIDPID Control Loop
89~99-      

*1: Supported in FX3G series ver.1.10 and later
*2: Supported in FX3U/FX3UC series ver.2.70 and later

Data Transfer 2

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
100,101-      
102ZPUSHBatch Store of Index Register---*
103ZPOPBatch POP of Index Register---*
104~109-      

*:Supported in FX3UC series ver.2.20 and later

Floating Point

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
110ECMPFloating Point Compare*
111EZCPFloating Point Zone Compare---
112EMOVFloating Point Move*
113~115-      
116ESTRFloating Point to Character String Conversion---
117EVALCharacter String to Floating Point Conversion---
118EBCDFloating Point to Scientific Notation Conversion---
119EBINScientific Notation to Floating Point Conversion---
120EADDFloating Point Addition*
121ESUBFloating Point Subtraction*
122EMULFloating Point Multiplication*
123EDIVFloating Point Division*
124EXPFloating Point Exponent---
125LOGEFloating Point Natural Logarithm---
126LOG10Floating Point Common Logarithm---
127ESQRFloating Point Square Root*
128ENEGFloating Point Negation---
129INTFloating Point to Integer Conversion*
130SINFloating Point Sine---
131COSFloating Point Cosine---
132TANFloating Point Tangent---
133ASINFloating Point Arc Sine-1---
134ACOSFloating Point Arc Cosine-1---
135ATANFloating Point Arc Tangent-1---
136RADFloating Point Degrees to Radians Conversion---
137DEGFloating Point Radians to Degrees Conversion---
138,139-      

*: Supported in FX3G series ver.1.10 and later

Data Operation 2

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
140WSUMSum of Word Data---*
141WTOBWORD to BYTE---*
142BTOWBYTE to WORD---*
143UNI4-bit Linking of Word Data---*
144DIS4-bit Grouping of Word Data---*
145,146-      
147SWAPByte Swap---
148-      
149SORT2Sort Tabulated Data 2---*

*: Supported in FX3UC series ver.2.20 and later

Positioning Control

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
150DSZRDOG Search Zero Return
151DVITInterrupt Positioning---
152TBLBatch Data Positioning Mode-*
153,154-      
155ABSAbsolute Current Value Read
156ZRNZero Return
157PLSVVariable Speed Pulse Output
158DRVIDrive to Increment
159DRVADrive to Absolute

*: Supported in FX3UC series ver.2.20 and later

Real Time Clock Control

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
160TCMPRTC data compare
161TZCPRTC data zone compare
162TADDRTC data addition
163TSUBRTC data subtraction
164HTOSHour to second conversion---
165STOHSecond to hour conversion---
166TRDRead RTC data
167TWRSet RTC data
168-      
169HOURHour Meter

External Device

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
170GRYDecimal to Gray Code Conversion
171GBINGray Code to Decimal Conversion
172~175-      
176RD3ARead form Dedicated Analog Block---
177WR3AWrite to Dedicated Analog Block---
178,179-      

Extension Function

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
180-      

Others

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
181-      
182COMRDRead device comment data---*
183-      
184RNDRandom Number Generation---
185-      
186DUTYTiming pulse generation---*
187-      
188CRCCyclic Redundancy Check---
189HCMOVHigh-speed counter move---

*: Supported in FX3UC series ver.2.20 and later

Block Data Operation

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
190,191-      
192BK+Block Data Addition---*
193BK-Block Data Subtraction---*
194BKCMP=Block Data Compare (S1) = (S2)---*
195BKCMP>Block Data Compare (S1) > (S2)---*
196BKCMP<Block Data Compare (S1) < (S2)---*
197BKCMP<>Block Data Compare (S1) ≠ (S2)---*
198BKCMP<=Block Data Compare (S1) ≦ (S2)---*
199BKCMP>=Block Data Compare (S1) ≧ (S2)---*

*: Supported in FX3UC series ver.2.20 and later

Character String Control

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
200STRBIN to Character String Conversion---*
201VALCharacter String to BIN Conversion---*
202$+Link Character Strings---
203LENCharacter String Length Detection---
204RIGHTExtracting Character String Data from the Right---
205LEFTExtracting Character String Data from the Left---
206MIDRRandom Selection of Character Strings---
207MIDWRandom Replacement of Character Strings---
208INSTRCharacter string search---*
209$MOVCharacter String Transfer---

*: Supported in FX3UC series ver.2.20 and later

Data Operation 3

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
210FDELDeleting Data from Tables---*
211FINSInserting Data to Tables---*
212POPShift Last Data Read [FILO Control]---
213SFR16-bit data n Bit Shift Right with Carry---
214SFL16-bit data n Bit Shift Left with Carry---
215~219-      

*: Supported in FX3UC series ver.2.20 and later

Data Comparison

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
220~223-      
224LD=Load Compare (S1) = (S2)
225LD>Load Compare (S1) > (S2)
226LD<Load Compare (S1) < (S2)
227-      
228LD<>Load Compare (S1) ≠ (S2)
229LD<=Load Compare (S1) ≦ (S2)
230LD>=Load Compare (S1) ≧ (S2)
231-      
232AND=AND Compare (S1) = (S2)
233AND>AND Compare (S1) > (S2)
234AND<AND Compare (S1) < (S2)
235-      
236AND<>AND Compare (S1) ≠ (S2)
237AND<=AND Compare (S1) ≦ (S2)
238AND>=AND Compare (S1) ≧ (S2)
239-      
240OR=OR Compare (S1) = (S2)
241OR>OR Compare (S1) > (S2)
242OR<OR Compare (S1) < (S2)
243-      
244OR<>OR Compare (S1) ≠ (S2)
245OR<=OR Compare (S1) ≦ (S2)
246OR>=OR Compare (S1) ≧ (S2)
247~249-      

Data Table Operation

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
250~255-      
256LIMITLimit Control---
257BANDDead Band Control---
258ZONEZone Control---
259SCLScaling (Coordinate by Point Data)---
260DABINDecimal ASCII to BIN Conversion---*1
261BINDABIN to Decimal ASCII Conversion---*1
262~268-      
269SCL2Scaling 2 (Coordinate by X/Y Data)---*2

*1: Supported in FX3UC series ver.2.20 and later
*2: Supported in FX3UC series ver.1.30 and later

External Device Communication

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
270IVCKInverter Status Check*1
271IVDRInverter Drive*1
272IVRDInverter Parameter Read*1
273IVWRInverter Parameter Write*1
274IVBWRInverter Parameter Block Write---
275IVMCInverter Multi Command*2*3*3
276ADPRWMODBUS Read / Write*4*5*5
277-      

*1: Supported in FX3G series ver.1.10 and later
*2: Supported in FX3G series ver.1.40 and later
*3: Supported in FX3U/FX3G series ver.2.70 and later
*4: Supported in FX3G series ver.1.30 and later
*5: Supported in FX3U/FX3UC series ver.2.40 and later

Data Transfer 3

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
278RBFMDivided BFM Read---*
279WBFMDivided BFM Write---*

*: Supported in FX3UC series ver.2.20 and later

High-Speed Processing 2

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
280HSCTHigh-Speed Counter Compare With Data Table---
281~289-      

Extension File Register Control

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
290LOADRLoad From ER-
291SAVERSave to ER---
292INITRInitialize R and ER---
293LOGRLogging R and ER---
294RWERRewrite to ER-*
295INITERInitialize ER---*
296~299-      

*: Supported in FX3UC series ver.1.30 and later

FX3U-CF-ADP Applied Instructions

FNC No.MnemonicFunctionApplicable FX PLC
FX3SFX3GFX3UFX3GCFX3UC
300FLCRTFile create / check--*-*
301FLDELFile delete / CF card format--*-*
302FLWRData write--*-*
303FLRDData read--*-*
304FLCMDFX3U-CF-ADP command--*-*
305FLSTRDFX3U-CF-ADP status read--*-*

*: Supported in FX3U/FX3UC series ver.2.61 and later