Product Features
Program Flow
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
00 | CJ | Conditional Jump | ○ | ○ | ○ | ○ | ○ |
01 | CALL | Call Subroutine | ○ | ○ | ○ | ○ | ○ |
02 | SRET | Subroutine Return | ○ | ○ | ○ | ○ | ○ |
03 | IRET | Interrupt Return | ○ | ○ | ○ | ○ | ○ |
04 | EI | Enable Interrupt | ○ | ○ | ○ | ○ | ○ |
05 | DI | Disable Interrupt | ○ | ○ | ○ | ○ | ○ |
06 | FEND | Main Routine Program End | ○ | ○ | ○ | ○ | ○ |
07 | WDT | Watchdog Timer Refresh | ○ | ○ | ○ | ○ | ○ |
08 | FOR | Start a FOR/NEXT Loop | ○ | ○ | ○ | ○ | ○ |
09 | NEXT | End a FOR/NEXT Loop | ○ | ○ | ○ | ○ | ○ |
Move and Compare
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
10 | CMP | Compare | ○ | ○ | ○ | ○ | ○ |
11 | ZCP | Zone Compare | ○ | ○ | ○ | ○ | ○ |
12 | MOV | Move | ○ | ○ | ○ | ○ | ○ |
13 | SMOV | Shift Move | ○ | ○ | ○ | ○ | ○ |
14 | CML | Complement | ○ | ○ | ○ | ○ | ○ |
15 | BMOV | Block Move | ○ | ○ | ○ | ○ | ○ |
16 | FMOV | Fill Move | ○ | ○ | ○ | ○ | ○ |
17 | XCH | Exchange | - | - | ○ | - | ○ |
18 | BCD | Conversion to Binary Coded Decimal | ○ | ○ | ○ | ○ | ○ |
19 | BIN | Conversion to Binary | ○ | ○ | ○ | ○ | ○ |
Arithmetic and Logical Operation
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
20 | ADD | Addition | ○ | ○ | ○ | ○ | ○ |
21 | SUB | Subtraction | ○ | ○ | ○ | ○ | ○ |
22 | MUL | Multiplication | ○ | ○ | ○ | ○ | ○ |
23 | DIV | Division | ○ | ○ | ○ | ○ | ○ |
24 | INC | Increment | ○ | ○ | ○ | ○ | ○ |
25 | DEC | Decrement | ○ | ○ | ○ | ○ | ○ |
26 | WAND | Logical Word AND | ○ | ○ | ○ | ○ | ○ |
27 | WOR | Logical Word OR | ○ | ○ | ○ | ○ | ○ |
28 | WXOR | Logical Exclusive OR | ○ | ○ | ○ | ○ | ○ |
29 | NEG | Negation | - | - | ○ | - | ○ |
Rotation and Shift Operation
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
30 | ROR | Rotation Right | ○ | ○ | ○ | ○ | ○ |
31 | ROL | Rotation Left | ○ | ○ | ○ | ○ | ○ |
32 | RCR | Rotation Right with Carry | - | - | ○ | - | ○ |
33 | RCL | Rotation Left with Carry | - | - | ○ | - | ○ |
34 | SFTR | Bit Shift Right | ○ | ○ | ○ | ○ | ○ |
35 | SFTL | Bit Shift Left | ○ | ○ | ○ | ○ | ○ |
36 | WSFR | Word Shift Right | ○ | ○ | ○ | ○ | ○ |
37 | WSFL | Word Shift Left | ○ | ○ | ○ | ○ | ○ |
38 | SFWR | Shift write [FIFO/FILO control] | ○ | ○ | ○ | ○ | ○ |
39 | SFRD | Shift read [FIFO control] | ○ | ○ | ○ | ○ | ○ |
Data Operation
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
40 | ZRST | Zone Reset | ○ | ○ | ○ | ○ | ○ |
41 | DECO | Decode | ○ | ○ | ○ | ○ | ○ |
42 | ENCO | Encode | ○ | ○ | ○ | ○ | ○ |
43 | SUM | Sum of Active Bits | ○ | ○ | ○ | ○ | ○ |
44 | BON | Check Specified Bit Status | ○ | ○ | ○ | ○ | ○ |
45 | MEAN | Mean | ○ | ○ | ○ | ○ | ○ |
46 | ANS | Timed Annunciator Set | - | ○ | ○ | ○ | ○ |
47 | ANR | Annunciator Reset | - | ○ | ○ | ○ | ○ |
48 | SQR | Square Root | - | - | ○ | - | ○ |
49 | FLT | Conversion to Floating Point | ○ | ○* | ○ | ○ | ○ |
*: Supported in FX3G series ver.1.10 and later
High-Speed Processing
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
50 | REF | Refresh | ○ | ○ | ○ | ○ | ○ |
51 | REFF | Refresh and filter adjust | - | - | ○ | - | ○ |
52 | MTR | Input Matrix | ○ | ○ | ○ | ○ | ○ |
53 | HSCS | High-speed counter set | ○ | ○ | ○ | ○ | ○ |
54 | HSCR | High-speed counter reset | ○ | ○ | ○ | ○ | ○ |
55 | HSZ | High-speed counter zone compare | ○ | ○ | ○ | ○ | ○ |
56 | SPD | Speed Detection | ○ | ○ | ○ | ○ | ○ |
57 | PLSY | Pulse Y Output | ○ | ○ | ○ | ○ | ○ |
58 | PWM | Pulse Width Modulation | ○ | ○ | ○ | ○ | ○ |
59 | PLSR | Acceleration/deceleration setup | ○ | ○ | ○ | ○ | ○ |
Handy Instruction
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
60 | IST | Initial State | ○ | ○ | ○ | ○ | ○ |
61 | SER | Search a Data Stack | ○ | ○ | ○ | ○ | ○ |
62 | ABSD | Absolute drum sequencer | ○ | ○ | ○ | ○ | ○ |
63 | INCD | Incremental drum sequencer | ○ | ○ | ○ | ○ | ○ |
64 | TTMR | Teaching Timer | - | - | ○ | - | ○ |
65 | STMR | Special Timer | - | - | ○ | - | ○ |
66 | ALT | Alternate State | ○ | ○ | ○ | ○ | ○ |
67 | RAMP | Ramp Variable Value | ○ | ○ | ○ | ○ | ○ |
68 | ROTC | Rotary Table Control | - | - | ○ | - | ○ |
69 | SORT | SORT Tabulated Data | - | - | ○ | - | ○ |
External FX Device
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
70 | TKY | Ten Key Input | - | - | ○ | - | ○ |
71 | HKY | Hexadecimal Input | - | - | ○ | - | ○ |
72 | DSW | Digital switch (thumbwheel input) | ○ | ○ | ○ | ○ | ○ |
73 | SEGD | Seven Segment Decoder | - | - | ○ | - | ○ |
74 | SEGL | Seven Segment With Latch | ○ | ○ | ○ | ○ | ○ |
75 | ARWS | Arrow Switch | - | - | ○ | - | ○ |
76 | ASC | ASCII code data input | - | - | ○ | - | ○ |
77 | PR | Print (ASCII Code) | - | - | ○ | - | ○ |
78 | FROM | Read From A Special Function Block | - | ○ | ○ | ○ | ○ |
79 | TO | Write To A Special Function Block | - | ○ | ○ | ○ | ○ |
External FX Device
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
80 | RS | Serial Communication | ○ | ○ | ○ | ○ | ○ |
81 | PRUN | Parallel Run (Octal Mode) | ○ | ○ | ○ | ○ | ○ |
82 | ASCI | Hexadecimal to ASCII Conversion | ○ | ○ | ○ | ○ | ○ |
83 | HEX | ASCII to Hexadecimal Conversion | ○ | ○ | ○ | ○ | ○ |
84 | CCD | Check Code | ○ | ○ | ○ | ○ | ○ |
85 | VRRD | Volume Read | ○ | ○*1 | ○*2 | - | ○*2 |
86 | VRSC | Volume Scale | ○ | ○*1 | ○*2 | - | ○*2 |
87 | RS2 | Serial Communication 2 | ○ | ○ | ○ | ○ | ○ |
88 | PID | PID Control Loop | ○ | ○ | ○ | ○ | ○ |
89~99 | - | | | | | | |
*1: Supported in FX3G series ver.1.10 and later
*2: Supported in FX3U/FX3UC series ver.2.70 and later
Data Transfer 2
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
100,101 | - | | | | | | |
102 | ZPUSH | Batch Store of Index Register | - | - | ○ | - | ○* |
103 | ZPOP | Batch POP of Index Register | - | - | ○ | - | ○* |
104~109 | - | | | | | | |
*:Supported in FX3UC series ver.2.20 and later
Floating Point
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
110 | ECMP | Floating Point Compare | ○ | ○* | ○ | ○ | ○ |
111 | EZCP | Floating Point Zone Compare | - | - | ○ | - | ○ |
112 | EMOV | Floating Point Move | ○ | ○* | ○ | ○ | ○ |
113~115 | - | | | | | | |
116 | ESTR | Floating Point to Character String Conversion | - | - | ○ | - | ○ |
117 | EVAL | Character String to Floating Point Conversion | - | - | ○ | - | ○ |
118 | EBCD | Floating Point to Scientific Notation Conversion | - | - | ○ | - | ○ |
119 | EBIN | Scientific Notation to Floating Point Conversion | - | - | ○ | - | ○ |
120 | EADD | Floating Point Addition | ○ | ○* | ○ | ○ | ○ |
121 | ESUB | Floating Point Subtraction | ○ | ○* | ○ | ○ | ○ |
122 | EMUL | Floating Point Multiplication | ○ | ○* | ○ | ○ | ○ |
123 | EDIV | Floating Point Division | ○ | ○* | ○ | ○ | ○ |
124 | EXP | Floating Point Exponent | - | - | ○ | - | ○ |
125 | LOGE | Floating Point Natural Logarithm | - | - | ○ | - | ○ |
126 | LOG10 | Floating Point Common Logarithm | - | - | ○ | - | ○ |
127 | ESQR | Floating Point Square Root | ○ | ○* | ○ | ○ | ○ |
128 | ENEG | Floating Point Negation | - | - | ○ | - | ○ |
129 | INT | Floating Point to Integer Conversion | ○ | ○* | ○ | ○ | ○ |
130 | SIN | Floating Point Sine | - | - | ○ | - | ○ |
131 | COS | Floating Point Cosine | - | - | ○ | - | ○ |
132 | TAN | Floating Point Tangent | - | - | ○ | - | ○ |
133 | ASIN | Floating Point Arc Sine-1 | - | - | ○ | - | ○ |
134 | ACOS | Floating Point Arc Cosine-1 | - | - | ○ | - | ○ |
135 | ATAN | Floating Point Arc Tangent-1 | - | - | ○ | - | ○ |
136 | RAD | Floating Point Degrees to Radians Conversion | - | - | ○ | - | ○ |
137 | DEG | Floating Point Radians to Degrees Conversion | - | - | ○ | - | ○ |
138,139 | - | | | | | | |
*: Supported in FX3G series ver.1.10 and later
Data Operation 2
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
140 | WSUM | Sum of Word Data | - | - | ○ | - | ○* |
141 | WTOB | WORD to BYTE | - | - | ○ | - | ○* |
142 | BTOW | BYTE to WORD | - | - | ○ | - | ○* |
143 | UNI | 4-bit Linking of Word Data | - | - | ○ | - | ○* |
144 | DIS | 4-bit Grouping of Word Data | - | - | ○ | - | ○* |
145,146 | - | | | | | | |
147 | SWAP | Byte Swap | - | - | ○ | - | ○ |
148 | - | | | | | | |
149 | SORT2 | Sort Tabulated Data 2 | - | - | ○ | - | ○* |
*: Supported in FX3UC series ver.2.20 and later
Positioning Control
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
150 | DSZR | DOG Search Zero Return | ○ | ○ | ○ | ○ | ○ |
151 | DVIT | Interrupt Positioning | - | - | ○ | - | ○ |
152 | TBL | Batch Data Positioning Mode | - | ○ | ○ | ○ | ○* |
153,154 | - | | | | | | |
155 | ABS | Absolute Current Value Read | ○ | ○ | ○ | ○ | ○ |
156 | ZRN | Zero Return | ○ | ○ | ○ | ○ | ○ |
157 | PLSV | Variable Speed Pulse Output | ○ | ○ | ○ | ○ | ○ |
158 | DRVI | Drive to Increment | ○ | ○ | ○ | ○ | ○ |
159 | DRVA | Drive to Absolute | ○ | ○ | ○ | ○ | ○ |
*: Supported in FX3UC series ver.2.20 and later
Real Time Clock Control
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
160 | TCMP | RTC data compare | ○ | ○ | ○ | ○ | ○ |
161 | TZCP | RTC data zone compare | ○ | ○ | ○ | ○ | ○ |
162 | TADD | RTC data addition | ○ | ○ | ○ | ○ | ○ |
163 | TSUB | RTC data subtraction | ○ | ○ | ○ | ○ | ○ |
164 | HTOS | Hour to second conversion | - | - | ○ | - | ○ |
165 | STOH | Second to hour conversion | - | - | ○ | - | ○ |
166 | TRD | Read RTC data | ○ | ○ | ○ | ○ | ○ |
167 | TWR | Set RTC data | ○ | ○ | ○ | ○ | ○ |
168 | - | | | | | | |
169 | HOUR | Hour Meter | ○ | ○ | ○ | ○ | ○ |
External Device
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
170 | GRY | Decimal to Gray Code Conversion | ○ | ○ | ○ | ○ | ○ |
171 | GBIN | Gray Code to Decimal Conversion | ○ | ○ | ○ | ○ | ○ |
172~175 | - | | | | | | |
176 | RD3A | Read form Dedicated Analog Block | - | - | ○ | - | ○ |
177 | WR3A | Write to Dedicated Analog Block | - | - | ○ | - | ○ |
178,179 | - | | | | | | |
Extension Function
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
180 | - | | | | | | |
Others
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
181 | - | | | | | | |
182 | COMRD | Read device comment data | - | - | ○ | - | ○* |
183 | - | | | | | | |
184 | RND | Random Number Generation | - | - | ○ | - | ○ |
185 | - | | | | | | |
186 | DUTY | Timing pulse generation | - | - | ○ | - | ○* |
187 | - | | | | | | |
188 | CRC | Cyclic Redundancy Check | - | - | ○ | - | ○ |
189 | HCMOV | High-speed counter move | - | - | ○ | - | ○ |
*: Supported in FX3UC series ver.2.20 and later
Block Data Operation
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
190,191 | - | | | | | | |
192 | BK+ | Block Data Addition | - | - | ○ | - | ○* |
193 | BK- | Block Data Subtraction | - | - | ○ | - | ○* |
194 | BKCMP= | Block Data Compare (S1) = (S2) | - | - | ○ | - | ○* |
195 | BKCMP> | Block Data Compare (S1) > (S2) | - | - | ○ | - | ○* |
196 | BKCMP< | Block Data Compare (S1) < (S2) | - | - | ○ | - | ○* |
197 | BKCMP<> | Block Data Compare (S1) ≠ (S2) | - | - | ○ | - | ○* |
198 | BKCMP<= | Block Data Compare (S1) ≦ (S2) | - | - | ○ | - | ○* |
199 | BKCMP>= | Block Data Compare (S1) ≧ (S2) | - | - | ○ | - | ○* |
*: Supported in FX3UC series ver.2.20 and later
Character String Control
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
200 | STR | BIN to Character String Conversion | - | - | ○ | - | ○* |
201 | VAL | Character String to BIN Conversion | - | - | ○ | - | ○* |
202 | $+ | Link Character Strings | - | - | ○ | - | ○ |
203 | LEN | Character String Length Detection | - | - | ○ | - | ○ |
204 | RIGHT | Extracting Character String Data from the Right | - | - | ○ | - | ○ |
205 | LEFT | Extracting Character String Data from the Left | - | - | ○ | - | ○ |
206 | MIDR | Random Selection of Character Strings | - | - | ○ | - | ○ |
207 | MIDW | Random Replacement of Character Strings | - | - | ○ | - | ○ |
208 | INSTR | Character string search | - | - | ○ | - | ○* |
209 | $MOV | Character String Transfer | - | - | ○ | - | ○ |
*: Supported in FX3UC series ver.2.20 and later
Data Operation 3
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
210 | FDEL | Deleting Data from Tables | - | - | ○ | - | ○* |
211 | FINS | Inserting Data to Tables | - | - | ○ | - | ○* |
212 | POP | Shift Last Data Read [FILO Control] | - | - | ○ | - | ○ |
213 | SFR | 16-bit data n Bit Shift Right with Carry | - | - | ○ | - | ○ |
214 | SFL | 16-bit data n Bit Shift Left with Carry | - | - | ○ | - | ○ |
215~219 | - | | | | | | |
*: Supported in FX3UC series ver.2.20 and later
Data Comparison
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
220~223 | - | | | | | | |
224 | LD= | Load Compare (S1) = (S2) | ○ | ○ | ○ | ○ | ○ |
225 | LD> | Load Compare (S1) > (S2) | ○ | ○ | ○ | ○ | ○ |
226 | LD< | Load Compare (S1) < (S2) | ○ | ○ | ○ | ○ | ○ |
227 | - | | | | | | |
228 | LD<> | Load Compare (S1) ≠ (S2) | ○ | ○ | ○ | ○ | ○ |
229 | LD<= | Load Compare (S1) ≦ (S2) | ○ | ○ | ○ | ○ | ○ |
230 | LD>= | Load Compare (S1) ≧ (S2) | ○ | ○ | ○ | ○ | ○ |
231 | - | | | | | | |
232 | AND= | AND Compare (S1) = (S2) | ○ | ○ | ○ | ○ | ○ |
233 | AND> | AND Compare (S1) > (S2) | ○ | ○ | ○ | ○ | ○ |
234 | AND< | AND Compare (S1) < (S2) | ○ | ○ | ○ | ○ | ○ |
235 | - | | | | | | |
236 | AND<> | AND Compare (S1) ≠ (S2) | ○ | ○ | ○ | ○ | ○ |
237 | AND<= | AND Compare (S1) ≦ (S2) | ○ | ○ | ○ | ○ | ○ |
238 | AND>= | AND Compare (S1) ≧ (S2) | ○ | ○ | ○ | ○ | ○ |
239 | - | | | | | | |
240 | OR= | OR Compare (S1) = (S2) | ○ | ○ | ○ | ○ | ○ |
241 | OR> | OR Compare (S1) > (S2) | ○ | ○ | ○ | ○ | ○ |
242 | OR< | OR Compare (S1) < (S2) | ○ | ○ | ○ | ○ | ○ |
243 | - | | | | | | |
244 | OR<> | OR Compare (S1) ≠ (S2) | ○ | ○ | ○ | ○ | ○ |
245 | OR<= | OR Compare (S1) ≦ (S2) | ○ | ○ | ○ | ○ | ○ |
246 | OR>= | OR Compare (S1) ≧ (S2) | ○ | ○ | ○ | ○ | ○ |
247~249 | - | | | | | | |
Data Table Operation
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
250~255 | - | | | | | | |
256 | LIMIT | Limit Control | - | - | ○ | - | ○ |
257 | BAND | Dead Band Control | - | - | ○ | - | ○ |
258 | ZONE | Zone Control | - | - | ○ | - | ○ |
259 | SCL | Scaling (Coordinate by Point Data) | - | - | ○ | - | ○ |
260 | DABIN | Decimal ASCII to BIN Conversion | - | - | ○ | - | ○*1 |
261 | BINDA | BIN to Decimal ASCII Conversion | - | - | ○ | - | ○*1 |
262~268 | - | | | | | | |
269 | SCL2 | Scaling 2 (Coordinate by X/Y Data) | - | - | ○ | - | ○*2 |
*1: Supported in FX3UC series ver.2.20 and later
*2: Supported in FX3UC series ver.1.30 and later
External Device Communication
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
270 | IVCK | Inverter Status Check | ○ | ○*1 | ○ | ○ | ○ |
271 | IVDR | Inverter Drive | ○ | ○*1 | ○ | ○ | ○ |
272 | IVRD | Inverter Parameter Read | ○ | ○*1 | ○ | ○ | ○ |
273 | IVWR | Inverter Parameter Write | ○ | ○*1 | ○ | ○ | ○ |
274 | IVBWR | Inverter Parameter Block Write | - | - | ○ | - | ○ |
275 | IVMC | Inverter Multi Command | ○ | ○*2 | ○*3 | ○ | ○*3 |
276 | ADPRW | MODBUS Read / Write | ○ | ○*4 | ○*5 | ○ | ○*5 |
277 | - | | | | | | |
*1: Supported in FX3G series ver.1.10 and later
*2: Supported in FX3G series ver.1.40 and later
*3: Supported in FX3U/FX3G series ver.2.70 and later
*4: Supported in FX3G series ver.1.30 and later
*5: Supported in FX3U/FX3UC series ver.2.40 and later
Data Transfer 3
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
278 | RBFM | Divided BFM Read | - | - | ○ | - | ○* |
279 | WBFM | Divided BFM Write | - | - | ○ | - | ○* |
*: Supported in FX3UC series ver.2.20 and later
High-Speed Processing 2
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
280 | HSCT | High-Speed Counter Compare With Data Table | - | - | ○ | - | ○ |
281~289 | - | | | | | | |
Extension File Register Control
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
290 | LOADR | Load From ER | - | ○ | ○ | ○ | ○ |
291 | SAVER | Save to ER | - | - | ○ | - | ○ |
292 | INITR | Initialize R and ER | - | - | ○ | - | ○ |
293 | LOGR | Logging R and ER | - | - | ○ | - | ○ |
294 | RWER | Rewrite to ER | - | ○ | ○ | ○ | ○* |
295 | INITER | Initialize ER | - | - | ○ | - | ○* |
296~299 | - | | | | | | |
*: Supported in FX3UC series ver.1.30 and later
FX3U-CF-ADP Applied Instructions
FNC No. | Mnemonic | Function | Applicable FX PLC |
---|
FX3S | FX3G | FX3U | FX3GC | FX3UC |
---|
300 | FLCRT | File create / check | - | - | ○* | - | ○* |
301 | FLDEL | File delete / CF card format | - | - | ○* | - | ○* |
302 | FLWR | Data write | - | - | ○* | - | ○* |
303 | FLRD | Data read | - | - | ○* | - | ○* |
304 | FLCMD | FX3U-CF-ADP command | - | - | ○* | - | ○* |
305 | FLSTRD | FX3U-CF-ADP status read | - | - | ○* | - | ○* |
*: Supported in FX3U/FX3UC series ver.2.61 and later